Loading Table Template
Ladder
Length |
0.2 |
0.4 |
0.6 |
0.8 |
1.0 |
2.0 |
3.0 |
4.0 |
5.0 |
Ref. Code |
1 LD 200 |
1 LD 400 |
1 LD 600 |
1 LD 800 |
3 LD 1000 |
4 LD 2000 |
5 LD 3000 |
1 LD 4000 |
1 LD 5000 |
Weight kg |
0.45 |
0.59 |
0.80 |
0.97 |
1.14 |
2.00 |
2.86 |
3.72 |
4.57 |
Max UDL kg |
N/A |
N/A |
Recommended for decorative-non structural applications only
|
Max Pnt kg |
N/A |
N/A |
Triangular
Length |
0.2 |
0.4 |
0.6 |
0.8 |
1.0 |
2.0 |
3.0 |
4.0 |
5.0 |
Ref. Code |
2 TR 200 |
2 TR 400 |
2 TR0.600 |
2 TR 800 |
3 TR 10000 |
4 TR 2000 |
5 TR 3000 |
2 TR 4000 |
2 TR 5000 |
Weight kg |
0.70 |
0.99 |
1.29 |
1.58 |
1.88 |
3.35 |
4.83 |
6.30 |
7.78 |
Max UDL kg |
N/A |
N/A |
N/A |
N/A |
500 |
486 |
415 |
342 |
259 |
Max Pnt kg |
N/A |
N/A |
N/A |
N/A |
300 |
160 |
121 |
100 |
80 |
Quad
Length |
0.2 |
0.4 |
0.6 |
0.8 |
1.0 |
2.0 |
3.0 |
4.0 |
5.0 |
Ref. Code |
2 QD 200 |
2 QD 400 |
2 QD 600 |
2 QD 800 |
3 QD 1000 |
4 QD 2000 |
5 QD 3000 |
2 QD 4000 |
2 QD 5000 |
Weight kg |
0.93 |
1.32 |
1.71 |
2.11 |
2.50 |
4.47 |
6.43 |
8.43 |
10.37 |
Max UDL kg |
N/A |
N/A |
N/A |
N/A |
629 |
615 |
581 |
550 |
501 |
Max Pnt kg |
|
|
|
|
|
|
|
|
|
Important: The loading figures for OPTI Trilite 100 Quad are based on a load being applied evenly
to both lower tubes. Individual loading of a single tube can reduce overall load bearing characteristics.
All lengths include spigots. UDL = Uniformly Distributed Load. Pnt = Point Load.
|